Key Features:
- Pressure ranges from vac to 20,000 psi
- +/-0.50% or +/- 1.00% of span accuracy
- Voltage and 4-20mA output options
- NEMA 4X
- All stainless steel wetted materials
- Highly configurable – broad selection of pressure ranges, output signals, pressure connections and electrical terminations
- FM Intrinsically safe or Non-incendive approval (optional)
- CRN approved
Applications:
Industrial and OEM Applications:
Machine Tool
Construction Equipment
Hydraulic and Pneumatic Systems
Process Applications:
Hydraulic
Refrigeration
HVAC
Pump Control
Medical
Reference Temperature
68°F (20°C)
Accuracy
±1.00% of span or ±0.50% (Option)
Terminal Point Method: includes non-linearity, hysteresis, nonrepeatability, zero offset and span
Best Fit Straight Line (BFSL)
± 0.25%, ± 0.40% of span, Add ±0.05% for ranges above 5000 psi
Pressure Ranges
15 to 20,000 psig, vacuum, compound to 200 psig
Stability
±0.5% Span/year at reference conditions
Durability
>10 million cycles
Wetted Material
Diaphragm: 17-4PH Stainless steel
Process Connection: 304 Stainless steel
Outputs
4-20mA, 1-5 Vdc, 1-6 Vdc, 1-11 Vdc
Non-Wetted Materials
Housing: 304 Stainless Steel