Model: JL676A
HP Aruba CX6100 48G 4SFP+ SWITCH
The Aruba ex 6100 Switch Series is modern family of entry level access switches ideal for enterprise branch offices and SMB networks. Optimized for reliable, simple and secure access, the CX 6100 switches provide a convenient wired access solution for enterprise networks supporting loT, mobile and cloud applications.
Key features
- Compact and fan less 12 port model for quiet deployment
- Enterprise-class Layer 2 connectivity with support for ACLs, robust QoS and static routing
- Convenient built-in 1 /1 OGbE uplinks and up to 370W of Class 4 PoE for support of loT devices
- Automated configuration and verification with Aruba NetEdit
- Software defined ready with REST APls
- Simplify adds, moves and changes with colorless ports
Technical specifications
Aruba 6100 48G 4SFP+ Switch (JL676A)
- 48x ports 10/100/1000Base-T ports
- 4x 1/10G SFP ports
- Internal (fixed) power supply (65W), fixed fans
- Dimensions: (H) 4.39 cm x (W) 44.2 cm x (D) 24.74 cm (1.73'' x 4'' x 9.74'')
- Weight: 3.42 kg (7.54 lbs)
MANAGEMENT PORTS
- 1x USB-C Console Port
- 1x USB Type-A Host port
Mounts in an EIA-standard 19 in. Telco rack or equipment cabinet. Horizontal surface mounting only. 2-post rack kit included.
ENVIRONMENTAL
- Operating temperature: 32°F to 113°F (0°C to 45°C) up to 5,000 ft. Derate -1°C degree C for every 1,000 ft. from 5,000 ft. to 10,000 ft.
- Operating Relative Humidity: 15% to 95% @ 104°F (40°C) noncondensing
- Non-Operating: -40°F to 158°F (-40°C to 70°C) up to 15,000 ft.
- Non-Operating Storage relative humidity: 15% to 90% @ 149°F (65°C) noncondensing
- Operating Altitude: 10,000 feet (3.04 km)
- Max Non-operating Altitude: 15,000 feet (4.6 km)
- Acoustics:
- Sound Power (LWAd) range: 0 – 4.3 Bel
- Sound Pressure (LpAm) (Bystander) range: 0 - 29.8 dB
- Primary airflow: Side to side (JL679A fanless)
SAFETY
- EN 60950-1/IEC 60950-1
- EN 60825
- CAN/CSA C22.2 No. 60950, 2nd Edition
- UL 60950-1, 2nd Edition
EMISSIONS
- FCC Class A
- VCCI Class A
- EN 55022/CISPR 22 Class A
IMMUNITY
- Generic: EN 55024, CISPR 24
- EN: EN 55024, CISPR 24
- ESD: IEC 61000-4-2
- Radiated Immunity: IEC 61000-4-3
- EFT/Burst: IEC 61000-4-4
- Surge: IEC 61000-4-5
- Conducted Immunity: IEC 61000-4-6
- Power frequency magnetic field: IEC 61000-4-8
- Voltage dips and interruptions: IEC 61000-4-11
- Harmonics: IEC/EN 61000-3-2
- Flicker: IEC/EN 61000-3-3