Please login to use this feature. You can use this feature to add the product to your favourite list.
Close
You have added this product to your favorite list. Check My Favourite
Close
You have removed this product from your favourite list.
Close
Please login to use this feature. You can use this feature to add the company to your favourites list.
Close
This company has been added successfully. Check My Favourite
Close
This company has been removed from your favourite list.
Close
Please login to use this feature. You can use this feature to add the company to your inquiry cart.
Close
This company has been added to your inquiry cart.
Close
This company has been removed from your inquiry cart.
Close
This product has been added to your inquiry cart.
Close
This product has been removed from your inquiry cart.
Close
Maximum number of Product/Company has been reached in inquiry cart.
Close
LUX & BRILLIANCE TECHNOLOGIES SDN. BHD.
LUX & BRILLIANCE TECHNOLOGIES SDN. BHD. 201601032161 (1203102-K)
Business
Hours
Monday - Friday 9:00 AM - 5:30 PM
Saturday - Sunday Closed
We′re closed on Public Holiday
Open Closed
Onesync Platinum + SSM
VISITORS
Social Media Link
  • facebook

29-Dec-2023

Features£º

1. 9.7-inch color touch LCD screen, easy to operate, display all parameters and histograms on the same screen

2. Fewer samples are required for testing: whole blood≤10ul, pre-diluted≤20ul

3. 60 samples/hour.

4. 21 parameters + 3 histograms

5. It can be turned on continuously for 24 hours

6. Automatically clean the sampler, counting pool and pipeline after starting up

7. Built-in thermal printer, external printer can be connected.

8. Electrical impedance method, cyanide-free detection of HGB

9. Fully intelligent blockage removal and alarm function

10. Both automatic calibration and manual calibration are available

11. Counting Mode: Venous, capilary, prediluted

12. Support LIS system.
 

Technical Parameter:

Model

BK-3100

Throughput

60 samples/hour

Principle

Impedance for WBC differentiation and WBC/RBC/PLT count; Colorimetric method for HGB

Channels

2

Parameters

21 parameters(including WBC, Mid#, Lym#, Gran#, Mid%, Lym%, Gran%, RBC, HGB, HCT, MCV, MCH, MCHC,RDW-SD, RDW-CV, PLT, MPV,PDW£¬PCT, P-LCR, P-LCC)

Histograms

3 histograms (including WBC, RBC, PLT histograms)

Sample Volume

Whole blood: 10μl, Prediluted: 20μl

Calibration

Manual, auto calibration

Counting Modes

Venous, capilary, prediluted

Printing Model

Auto print, manual print

LIS

Support Bi-directional LIS

Language

Chinese, English, Spanish, French, Russian, Ukrainian

Reagent

Diluent 10L, Hemolytic agent 250ml, Probe cleanser: 50ml

Data Input

9.7-inch touch screen, mouse, keyboard (optional)

Output

Internal printer, support external printer

Printer paper

57*30mm

Interface

4 USB ports, network port£¬RS232 serial port.

Storage

100,000 results with histogram

Unclog

High voltage burn, reverse high-pressure flush

Work Temperature

15-30°C

Power Supply

100~240 AC, 50/60Hz, 150VA

Relative Humidity

30þj¡«85þj

Atmospheric Pressure

70.0kPa-110.0kPa

Carry-over rate

Parameter

WBC

RBC

HGB

PLT

CV

≤ 1.5%

≤ 1%

≤ 1%

≤ 3%

Background

Parameter

WBC

RBC

HGB

HCT

PLT

Background

≤ 0.3×109/L

≤ 0.03×1012/L

≤ 1 g/L

≤ 0.5%

≤ 10×109/L

Linearity

Parameter

Measurement range

CV

WBC

(0.5~10.00×109)/L
(10.10~99.9×109)/L

(±0.5×109)/L
±5%

RBC

(0.05~1.00×1012)/L (1.01~9.99×1012)/L

(±0.05×1012)/L
±5%

HGB

(2~70g)/L
(71~300.0g)/L

(±2.0g)/L
±2%

PLT

(10~100×109)/L
(101~999×109)/L

(±10.0×109)/L
±8%

Precision

Parameter

Whole blood (CV)

Pre-diluted£¨CV£© 

Measurement range

WBC

≤ 2.0%

≤ 4.0%

(4.0-15.0×109)/L

RBC

≤ 1.6%

≤ 3.0%

(3.5-6.0×1012)/L

HGB

≤ 1.6%

≤ 3.0%

(110.0-180.0g)/L

MCV

≤1.0%

≤2.0%

(70.0-120.0)fL

PLT

≤ 4.0%

≤8.0%

(150.0-500.0×109)/L

External Size(W*D*H)

295*467*418mm

Packed Size(W*D*H)

Instrument: 404*564*616mm; Reagent: 480*480*480mm

Net weight

19 KG

Gross weight

Instrument:31KG; Reagent::25Kg

Send your message to LUX & BRILLIANCE TECHNOLOGIES SDN. BHD.
Thank you for your inquiry!
Our Customer Support will be in touch with you shortly.
Your Name *
Your Company Name
Your Email *
Your Contact Number *
Subject *
Message *
Captcha *
Main Office

LUX & BRILLIANCE TECHNOLOGIES SDN. BHD. 201601032161 (1203102-K)
7442, Jalan Bagan Lalang, Taman Carissa Villa, 13400 Butterworth, Penang, Malaysia.

Tel:
Fax:

Email:
Website: https://www.lnbtec.com
Website: https://lnbtec.newpages.com.my/
Website: https://lnbtec.onesync.my/

Other Office

KL Office
Jalan Kuchai Lama, Kuala Lumpur, Malaysia.

Tel:
Tel:
Email:

1
Hello! Thanks for visiting my site. Please press Start button to Contact with Admin :)

Start

Browse by : Home - Classifieds - Companies - Location - Tags - Products - News & Promotion - Job Vacancy - Mobile Website - Google - SEO Results

NEWPAGES

  • US 15800
  • GB 10909
  • CA 9303
  • AU 7153
  • BR 2099
  • IE 1464
  • NZ 1378
  • IN 1327
People Online
Seni Jaya Logo
Brochure
Download
Our PackageContact Us