- ¡öDigital indicator in bar graph display
- ¡ö2 points setting or 4 points settings are possible
- ¡öScaling function is available in digital display
- Model Designation
-
193 ¡õ - ¡õ - ¡õ A B C Specifications
1933 1934 Bar Graph Display Display LED (Color: Red) Bar dots 101 Scale length 100 mm¡¡(1.5 mm width) Accuracy ±(1% of FS + 1 digit) Response time 0.5s Scale plate Black Aluminum(White scale & white characters) Digital Display Display 0-9999¡¡LED (Color: Red)(8×4 mm) Scaling full scale・・・-1999 to 9999
off set value・・・-1999 to 9999
not available for reverse proportion to input value.Resolution 1/2000 Sampling period 12 times/sec. Accuracy ±(0.5% of FS + 1 digit) Setting range H £º(set value of L + 1%)-100%
L £º(set value of H - 1%)-0%HH £º(set value of H + 1%)to 100%
H £º(set value of HH - 1%)to(set value of L + 1%)
L £º(set value of H - 1%)to(set value of LL + 1%)
LL £º(set value of L - 1%)to 0%Relay output H : 1 transfer
L : 1 transferH / L : 1 “a”contact
HH / LL : 1 transfer *Hysteresis 1% of FS Contact capacity AC 125 V, 0.5 A Insulation resistance All terminals - Case¡¡DC 500 V, More than 10 MΩ Withstanding voltage Input terminals - Case AC 1500 V 1min. Input terminals – Power Supply terminals AC 1500 V 1min.(AC) Input terminals – Power Supply terminals AC 500 V 1min.(DC 24 V) Relay contacts – Other Circuits AC 1000 V 1min. Power supply AC 85-264 V¡¡50/60 Hz
DC 24 V¡¡± 15%
DC 5 V¡¡± 5%Power consumption 10 VA(AC 85-264 V)
4 W(DC 24 V ± 15%)
2 W(DC 5 V ± 15%)Operating temperature 0 to 45°C Storage temperature -20 to 70°C Weight Applox. 420 g * HH and H£ºCommon terminals are common, LL and L£ºCommon terminals are common
Input Specifications
Code Input Signal Input Impedance 1 DC 0-1 mA 200 Ω 2 DC 4-20 mA 10 Ω 3 DC 0-1 V 1 MΩ 4 DC 1-5 V 5 DC 0-5 V No. 1 2 3 4 5 6 7 8 9 10 11 12 Max. value 1 1.2 1.5 2 2.5 3 4 5 6 7.5 8 9 Division No. 50 24 30 40 50 30 40 50 30 37.5 40 45