- Simple Operation by Interactive Key Input.
- Operation Monitor visualizes Controller Status, Temp and Temp. Changing.
- Incorporates with maximum 99 steps, 99 patterns program controller with repeat function.
- Loaded with Total Operation Hours Timer.
- Exhaust damper allows quick exhaust and cooling of inside.
- Accumulated timer function useful for maintenance and management is equipped as standard.
- Cable port useful for a monitor for temperature during testing is equipped as standard.
Item Code | 211783 |
---|---|
Model | DH612 |
System | Forced convection and ventilation |
Operating temp. range | Room temp. + 15 to 360¡æ |
Temp. control accuracy (JTM K05) | ±0.2¡æ£¨at 360¡æ£© |
Temp. fluctuation (JIS) | ±1.0¡æ£¨at 360¡æ£© |
Temp. distribution accuracy (JTM K05) | ±2.5¡æ£¨at 360¡æ£© |
Temp. gradient (JIS) | ±12¡æ£¨at 360¡æ£© |
Time to attain max. temp. | Approx. 60 min. (to 360¡æ) |
Temp. control system | PID control with a micro computer |
Temp. and time setting system | Digital Setting by UP/DOWN Key |
Timer display range | Fixed value operation for 1 min. to 99 hr 59 min. and 24hr. setting |
Operation and manipulation functions | Fixed temp., Auto-start, Auto-stop, Quick auto stop, program (Max.99 steps, 99 patterns, repeat) |
Additional functions | Calendar timer (max. 24 Hrs.), Integration time (max. 65535Hrs.), Clock, Calibration off-set, Display the amount of Power consumption |
Additional functions | CO2 discharge/Heater operation amount, Power failure recovery mode, User setting information save and recall, Wind velocity changeable function |
Sensor | Double K-thermocouple |
Heater | Stainless pipe heater with a fan |
Nominal heater capacity | 3.75kW |
Blower fan (motor) | Axial flow fan (capacitor motor) |
Cable port | I.D. 33 mm (rear) |
Heat insulator | Glass wool |
Other additional mechanism | Exhaust damper (manual) |
Safety device | Self diagnosis functions(Sensor, Fan, Heater, Relay, Triac, Automatic overheat prevention), Independent overheat prevention, Key lock function, Electric leakage breaker, Door switch |
No.of shelf stages/peg pitch | 9 stages/60 mm |
Accessories Shelf | 2 pcs |
Accessories Shelf support | 4 pcs |
Internal dimensions£¨W×D×H mm£© | 600×600×600mm |
External dimensions£¨W×D×H mm£© | 1200×780×1000mm |
Remarks(dimensions) | 216L |
Power Source |
AC220V 19A Single-phase |
Weight | 156kg |
Maintenance and warranty