Please login to use this feature. You can use this feature to add the product to your favourite list.
Close
You have added this product to your favorite list. Check My Favourite
Close
You have removed this product from your favourite list.
Close
Please login to use this feature. You can use this feature to add the company to your favourites list.
Close
This company has been added successfully. Check My Favourite
Close
This company has been removed from your favourite list.
Close
Please login to use this feature. You can use this feature to add the company to your inquiry cart.
Close
This company has been added to your inquiry cart.
Close
This company has been removed from your inquiry cart.
Close
This product has been added to your inquiry cart.
Close
This product has been removed from your inquiry cart.
Close
Maximum number of Product/Company has been reached in inquiry cart.
Close
Hanna Instruments (M) Sdn Bhd
Hanna Instruments (M) Sdn Bhd 198801005697 (173054-W)
Business
Hours
Monday - Friday 8:30 AM - 5:30 PM
Saturday - Sunday Closed
We′re closed on Public Holiday
Open Closed
SSM
VISITORS

Penang,Selangor,Kuala Lumpur (KL),Sabah,Kota Kinabalu,Petaling Jaya,Sungai Nibong - HI981413 Groline Nutrient Dosing System

29-Apr-2024

Engineered to be an inexpensive solution for the hydroponic or greenhouse grower to maintain the ideal nutrient solution concentration level in the reservoir tank. The HI981413 GroLine Nutrient Dosing System is a complete solution with advanced process controller and a built in chemical dosing pump. Simply insert the probe and injection valve in-line with the re-circulation pump and supply the stock fertilizer to be dosed.
  • All in one solution for maintaining the proper nutrient levels
  • Industrial process probe with 1/2'' NPT threads for insertion into a re-circulation line
  • Available in three configurations including complete kit with panel mounted flow cell

HI981413 Nutrient Dosing System is designed to maintain the concentration of fertilizer nutrient solution used in hydroponics and irrigation water. The HI981413 uses an amperometric conductivity sensor to measure the amount of fertilizer in the solution. The meter can be programmed to display results as EC (electrical conductivity) or as TDS (total dissolved solids). The EC results are displayed as mS/cm while TDS is displayed as ppm with a selectable conversion factor from 0.45 to 0.99. The HI981413 was developed as a cost-effective solution for the horticulturist to maintain the ideal fertilizer concentrations by placing the probe and injection valve in-line with the re-circulation pump to provide the chemical to be dosed.



Multi-color LCD

The HI981413 features a multi-colored LCD to show the status of the pool controller. The display is green during normal opperation, yellow if the control is not enabled, or flashes red when an alarm is triggered.

Intuitive LCD

Both conductivity or TDS and temperature are displayed with status icons that show when the pump is dosing and the control mode status.

Programmable Alarm System

Hanna controllers allow users to enable or disable the low and high-level alarms for EC/TDS. When an alarm is activated, all dosing will stop. For added safety, the alarm system also offers overdosing protection in that if the set point value is not corrected within a programmed time interval then the meter will go into alarm status.


 

On-Screen Features

flow rate

Adjustable Flow Rate
The flow rate from the dosing pumps is adjustable from 0.5 to 3.5L/h. Larger bodies of water require more chemical to be dosed than smaller ones in per unit of time. The adjustable flow rate, like the proportional band, allows for better control in maintaining a desired set point .

Automatic Proportional Pump Control

Automatic Proportional Pump Control
The peristaltic dosing pump can be controlled by simple on/off or more advanced proportional control which helps prevents overshooting of the set point. When using proportional control the flow rate that is programmed, will be impacted by the proportional band used. The closer the reading is to the set point the longer it takes for the peristaltic pump to complete one revolution. If the reading is outside the proportional band then the amount of time it takes to complete one revolution is based on the flow rate programmed.

Tank Level/Flow Switch Input

Acid Tank Level/Flow Switch Input
The BL100 allows for a connection to an optional level controller or flow switch. This input can be used to disable the dosing pump when there is no chemical left in the reservoir tank or there is no flow due to the pump being turned off.


 

Built-in Dosing Pump

GroLine Peristaltic Pump

Peristaltic Dosing Pump

The HI981413 features a peristaltic dosing pump that is superior to diaphragm versions due to the ability to self-prime when there is no liquid in the uptake line.

Brushless Motor

The brushless motor does not have nay gears or brushes that can wear out. A brushless design provides for a long life and little maintenance. The compact stepper motor allows for very precision control over the dosing of the chemical.

Long-life Peristaltic Tubing

The industrial grade peristaltic tubing is chemical resistant and provides for a relatively long-life. As tubing stretches over time it can be easily replaced. No special tools required.


 

Conductivity electrode with flow cell


EC probe mounted in flow thorugh cell

Three Configuration Options

The HI981413 is available in multiple configurations including a meter only, meter and probe, and
 a complete package that includes bypass loop
 and panel mounted flow through cell. All models include aspiration tubing with filter and dispensing tubing with injection valve.

HI30003 Amperometric Conductivity/Temperature Probe

The HI981413 uses the HI30003 probe that incorporates both conductivity and temperature sensors and connects to the controller with a single waterproof Quick Connect DIN connector.

NPT Threads for In-line and Tank Mounting

The ABS body of the probe has a 1/2” threaded fitting for insertion to an in-line “T” fitting or the flow cell. The back end part of the probe has 3/4” NPT threads for submersion/ tank mounting. The probe body has a hex fitting for tightening snuggly with a wrench. 
 

SKU HI981413-web
Product Name Groline Nutrient Dosing System-HI981413
Quote Required Yes
EC Range 0.00 to 10.00 mS/cm
EC Resolution 0.01 mS/cm
EC Accuracy 2% F.S.
EC Calibration User calibration
TDS Range 0 to 9900 ppm, depends on TDS factor
i.e. with TDS factor 0.5, range 50 to 5000 ppm
with TDS factor 0.7, range 70 to 7000 ppm
TDS Resolution 1 ppm
TDS Accuracy 2% F.S.
EC/TDS Temperature Compensation automatic
Temperature Correction Coefficient β can be set from 0%/°C to 2.4%/°C; default is 1.9%/°C
EC to TDS Conversion Factor TDS factor selectable from 0.45 to 0.99
EC/TDS Dosing Set Point on/off control using adjustable set point (0.10 to 10.00 mS/cm; 45 to 9900 ppm, depends on TDS factor)
proportional control 0.10 to 10.00 mS/cm; 45 to 9900 ppm, depends on TDS factor
EC/TDS Proportional Band 0.05 to 1.00 mS/cm; 23 to 990 ppm, depends on TDS factor
EC/TDS Hysteresis Band 0.05 to 0.50 mS/cm; 23 to 495 ppm, depends on TDS factor
Temperature Range -5.0 to 105.0°C; 23.0 to 221.0°F*
Temperature Resolution 0.1°C; 0.1°F
Temperature Accuracy ±0.5°C; 1°F
Dosing Control startup delay timer at power-on (0 to 600 sec.)
Pump flow control 0.5 to 3.5 Liter/hour (0.13 to 0.92 Gallon/hour) and maximum output pressure 1 atm (14 psi)
manual control for pump priming (defined in setup)
Alarm Relay Set Point triggered after 5 sec. if the controller records consecutive readings over or under threshold values
Over Dosing Control overtime protection (1 to 180 min. or Off)
Digital Input Signal galvanically isolated external switches can be attached to stop the pump and activate the alarm (low reagent level) when the switch is open and level alarm is configured in Setup
Backlight intuitive alarm system, using red, yellow and green color coded backlight
Power Consumption 15 VA
Enclosure wall mounted, built-in pump
Power Supply 100 - 240 Vac, 50/60 Hz
Environment 0 to 50°C (32 to 122°F); RH max. 95% non-condensing
IP Rating IP65
Dimensions 90 x 142 x 80 mm (3.5 x 5.6 x 1.8”)
Weight 908 g (36 oz.)
Ordering Information HI981413-00 is supplied with HI981413 controller, HI30033 EC/TDS/temperature probe, HI7031-012 conductivity calibration solution (1413 μS/cm - 120 ml), plastic beaker, power connection cable, instruction manual and quality certificates for instrument and probe.
Notes *The temperature range may be limited by the probe’s limits.
 
Send your message to Hanna Instruments (M) Sdn Bhd
Thank you for your inquiry!
Our Customer Support will be in touch with you shortly.
Your Name *
Your Company Name
Your Email *
Your Contact Number *
Subject *
Message *
Captcha *
Main Office

Hanna Instruments (M) Sdn Bhd 198801005697 (173054-W)
11A, Jalan PJS 11/20, Bandar Sunway, 46150 Petaling Jaya, Selangor, Malaysia.

Tel:

Email:
Website: https://www.hannamalaysia.com
Website: https://hannamalaysia.newpages.com.my/
Website: https://hannamalaysia.n.my/

Other Office

Hanna Instruments (M) Sdn Bhd (Penang)
N0. 303-2-27, Krystal Point, Jalan Sultan Azlan Shah, 11900 Sungai Nibong, Penang, Malaysia.

Tel:
Fax:
Email:

Hanna Instruments (M) Sdn Bhd (Sabah)
No. 4-1, 1st Floor, Plaza Kingfisher, Jalan Plaza Kingfisher 5, Inanam, 88450 Kota Kinabalu, Sabah, East Malaysia.

Tel:
Fax:
Email:

Browse by : Home - Classifieds - Companies - Location - Tags - Products - News & Promotion - Job Vacancy - Mobile Website - Google - SEO Results

NEWPAGES

  • US 11126
  • GB 8822
  • CA 7762
  • AU 6475
  • IE 4113
  • NZ 1353
  • IN 671
  • RU 518
People Online
Seni Jaya Logo
Brochure
Download
Our PackageContact Us