Please login to use this feature. You can use this feature to add the product to your favourite list.
Close
You have added this product to your favorite list. Check My Favourite
Close
You have removed this product from your favourite list.
Close
Please login to use this feature. You can use this feature to add the company to your favourites list.
Close
This company has been added successfully. Check My Favourite
Close
This company has been removed from your favourite list.
Close
Please login to use this feature. You can use this feature to add the company to your inquiry cart.
Close
This company has been added to your inquiry cart.
Close
This company has been removed from your inquiry cart.
Close
This product has been added to your inquiry cart.
Close
This product has been removed from your inquiry cart.
Close
Maximum number of Product/Company has been reached in inquiry cart.
Close
Hanna Instruments (M) Sdn Bhd
Hanna Instruments (M) Sdn Bhd 198801005697 (173054-W)
Business
Hours
Monday - Friday 8:30 AM - 5:30 PM
Saturday - Sunday Closed
We′re closed on Public Holiday
Open Closed
SSM
VISITORS

Penang,Selangor,Kuala Lumpur (KL),Sabah,Kota Kinabalu,Petaling Jaya,Sungai Nibong - Services HI98165 Professional Portable Cheese pH Meter

04-Jul-2017

The HI98165 is a rugged, waterproof, portable Foodcare pH meter that measures pH and temperature using the specialized FC2423 cheese pH electrode.  This professional, waterproof meter complies with IP67 standards. The HI98165 is supplied with all necessary accessories to perform a pH/temperature measurement packaged into a durable thermoformed carrying case  that holds the meters, probes and calibration buffers securely in place.

  • Quick Connect DIn Connector
  • USB Connection for Data Transfer
  • Dedicated Help Button

pH is an essential measurement throughout the entire cheesemaking process. From the initial measurements of incoming milk to the final measurements of ripened cheese, pH is the most important parameter for cheese quality and safety control.

Acidification of milk begins with the addition of bacterial culture and rennet. The bacteria consume lactose and create lactic acid as a byproduct of fermentation. The lactic acid produced will cause the pH of the milk to go down. Once the milk reaches a particular pH, the rennet is added. The enzymes in rennet help to speed up curdling and create a firmer substance. For cheesemakers that dilute their rennet, the pH of the dilution water is also critical; water that is near pH 7 or higher can deactivate the rennet, causing problems with coagulation.

Once the curds are cut, stirred, and cooked, the liquid whey must be drained. The pH of whey at draining directly affects the composition and texture of the final cheese product. Whey that has a relatively high pH contributes to higher levels of calcium and phosphate and results in a stronger curd. Typical pH levels at draining can vary depending on the type of cheese; for example, Swiss cheese is drained between pH 6.3 and 6.5 while Cheddar cheese is drained between pH 6.0 and 6.2.

During brining, the cheese soaks up salt from the brine solution and loses excess moisture. The pH of the brine solution should be close to the pH of the cheese, ensuring equilibrium of ions like calcium and hydrogen. If there is an imbalance during brining, the final product can have rind defects, discoloration, a weakened texture, and a shorter shelf life.

Cheeses must fall within a narrow pH range to provide an optimal environment for microbial and enzymatic processes that occur during ripening. Bacterial cultures used in ripening are responsible for familiar characteristics such as the holes in Swiss cheese, the white mold on Brie rinds, and the aroma of Limburger cheese. A deviation from the ideal pH is not only detrimental to the ecology of the bacteria, but also to the cheese structure. Higher pH levels can result in cheeses that are more elastic while lower pH levels can cause brittleness.

Cheese products can provide a number of challenges for the person that needs to measure pH. Cheese products tend to be solid to semi-solids. Both types of samples will coat the sensitive glass membrane surface and/or clog the reference junction. The FC2423 that is supplied with the HI98165 is designed specifically for measuring pH in cheese. From a conic tip shape in a durable 5 mm diameter stainless steel body for easy penetration into cheese without leaving a large hole to an open junction that resist clogging; the FC2423 is an ideal general-purpose pH electrode for cheese. The FC2423 connects to the HI98165 with a quick-connect, waterproof DIN connector, allowing for a secure, non-threaded attachment.

The HI99165 uses the stainless steel FC2423 amplified pH electrode. This specialized electrode offers numerous features that improve pH testing for cheese producers. The robust stainless steel sheath paired with the conical sensing tip allows for penetration in cheese at various points throughout the production process. An integrated temperature sensor also ensures that all pH measurements are compensated for temperature without the need for a separate temperature probe.

Probe

Stainless Steel Body

Stainless Steel Body

The AISI 316 stainless steel body offers durability in the production facility and can withstand chloride concentrations that cause corrosion in other types of alloys.
 

conical glass tip

Conic Glass Tip

The conical shaped tip design allows for penetration into solids, semi-solids, and emulsions for the direct measurement of pH in samples such as cheese.
 

Temp Sensor

Built-In Temperature Sensor

Errors in calibration and measurement are eliminated with the Automatic Temperature Compensation provided by the integrated temperature sensor.

Besides being supplied with a unique pH electrode made for cheese, the HI98165 has the Hanna's unique CAL Check™ feature that alerts the user to potential problems during the calibration process. This is a very important for the food processor since it is likely that the probe will be coated with the solids found in the food product being measured. This coating can easily lead to errors in pH measurement. By comparing previous calibration data to the current calibration, the meter will inform the user, with display prompts, when the probe needs to be cleaned, replaced, or if the pH buffer might be contaminated. After calibration, the overall probe condition is displayed on screen as a percentage from 0 to 100% in increments of 10%. The probe condition is affected by both the offset and slope characteristics of the pH electrode, both of which can be found in the GLP data.

Pressing the “AutoHold” virtual key in measurement mode, the meter will freeze and automatically log a stable reading. An “out of calibration range” warning can be enabled that will alert the user when a reading is not within the bracket of calibrated pH values.

The log-on-demand mode allows the user to record and save up to 200 samples. The logged data, along with the associated GLP data, can then be recalled or transferred to a PC with Hanna’s HI920015 micro USB cable and HI92000 software for traceability in record keeping for specific product batches. GLP data includes date, time, calibration buffers, offset, and slope, and is directly accessible by pressing the dedicated GLP key.

A contextual help menu based on the screen that is currently being viewed can be accessed at any time by the press of a dedicated button.

The high contrast, graphic LCD screen is easy to view outdoors in bright sunlight as well as in low-lit areas with the backlight. A combination of dedicated and virtual keys allows for easy, intuitive meter operation in a choice of languages.

The compact, durable HI720165 carrying case is thermoformed to hold all necessary components for taking a field measurement, including the meter and electrode, beakers, buffer solutions and cleaning solutions.

 

On-Screen Features

Setup screen
Our extensive setup screen features a host of configurable options such as time, date, temperature units and language for help screens and guides.

Calibration
pH calibration features detailed CAL Check™ messages. Users are guided through the calibration procedure with step-by-step on-screen instructions.

GLP

GLP
Comprehensive GLP functions are directly accessible by pressing the GLP key. Calibration data, including: date, time, offset, slope and buffers used in the last calibration can be reviewed.

Features/Benefits:

Ergonomic, rugged, waterproof (IP67) design

Supplied with FC2423 Foodcare pH/Temperature electrode

  • Durable stainless steel body that is only 5 mm in diameter
  • Conic tip shape for easy penetration into semi-solids
  • Open junction design that resist clogging from food solids
  • Built in temperature sensor for temperature compensated measurements

Five-point pH calibration with seven standard buffers and five custom buffers

CAL Check

  • Alerts user to potential problems during calibration including when to clean electrode and possible buffer contamination
  • Displays overall condition of the pH electrode after calibration that is based on the offset and slope characteristics

Log-on-demand

  • Store measurement data at the press of a button

AutoHold

  • Freezes displayed measurement reading upon stabilization

 

GLP Features

  • GLP data including date, time, pH calibration buffers, offset, and slope
  • GLP data stored with logged data for traceability

Calibration timeout to alert the user at a defined interval when the calibration has expired

Multiple language selection

200 hour battery life with battery level displayed on measurement screen

Menu driven for ease of use with virtual-key extended functionality

Contextual help at the press of a button

Backlit, graphic LCD

Connectivity

  • PC connectivity via a sealed opto-isolated micro USB and HI92000 software

SKU HI98165
Product Name Professional Portable Cheese pH Meter - HI98165
Quote Required Yes
pH Range -2.0 to 20.0 pH; -2.00 to 20.00 pH; -2.000 to 20.000 pH
pH Resolution 0.1 pH; 0.01 pH; 0.001 pH
pH Accuracy ±0.1; ±0.002 pH
pH Calibration up to five point calibration, seven standard buffers available (1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45) + five custom buffers
pH Temperature Compensation manual or automatic from -20.0 to 120.0°C (-4.0 to 248.0°F)
pH Input impedence 10¹² Ohms
mV Range ±2000 mV
mV Resolution 0.1 mV
mV Accuracy ±0.2 mV
Temperature Range -20.0 to 120.0°C (-4.0 to 248.0°F)
Temperature Resolution 0.1°C (0.1°F)
Temperature Accuracy ±0.4°C (±0.8°F) (excluding probe error)
Temperature Calibration manual or automatic from -20.0 to 120.0°C (-4.0 to 248.0°F)
pH Electrode FC2423 Foodcare stainless steel body, pH electrode with internal temperature sensor, quick connect DIN connector and 1 m (3.3’ cable)
Logging Memory 200 samples (100 pH and 100 mV range)
Connectivity opto-isolated USB with optional HI 92000 software and micro USB cable
Automatic Shut-Off user selectable
GLP Yes
Battery Type/Life 1.5V AA batteries (4) / approximately 200 hours of continuous use without backlight (50 hours with backlight)
IP Protection IP67
Environment 0 to 50°C (32 to 122°F); RH 100%
Dimensions 185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4”)
Weight 400 g (14.2 oz.)
Ordering Information HI98165 is supplied with FC2423 PVDF body pH electrode, HI7004M pH 4.01 buffer solution (230 mL), HI7007M pH 7.01 buffer solution (230 mL), HI700642 electrode cleaning solution for cheese residues sachet (2), 100 mL plastic beaker (2), 1.5V AA batteries (4), HI92000 PC software, HI920015 micro USB cable, instruction manual with quick start guide, instrument quality certificate and HI720165 hard carrying case.

Send your message to Hanna Instruments (M) Sdn Bhd
Thank you for your inquiry!
Our Customer Support will be in touch with you shortly.
Your Name *
Your Company Name
Your Email *
Your Contact Number *
Subject *
Message *
Captcha *
Main Office

Hanna Instruments (M) Sdn Bhd 198801005697 (173054-W)
11A, Jalan PJS 11/20, Bandar Sunway, 46150 Petaling Jaya, Selangor, Malaysia.

Tel:

Email:
Website: https://www.hannamalaysia.com
Website: https://hannamalaysia.newpages.com.my/
Website: https://hannamalaysia.n.my/

Other Office

Hanna Instruments (M) Sdn Bhd (Penang)
N0. 303-2-27, Krystal Point, Jalan Sultan Azlan Shah, 11900 Sungai Nibong, Penang, Malaysia.

Tel:
Fax:
Email:

Hanna Instruments (M) Sdn Bhd (Sabah)
No. 4-1, 1st Floor, Plaza Kingfisher, Jalan Plaza Kingfisher 5, Inanam, 88450 Kota Kinabalu, Sabah, East Malaysia.

Tel:
Fax:
Email:

Browse by : Home - Classifieds - Companies - Location - Tags - Products - News & Promotion - Job Vacancy - Mobile Website - Google - SEO Results

NEWPAGES

  • US 12910
  • GB 9872
  • CA 7579
  • AU 5255
  • IE 2127
  • NZ 1273
  • IN 1243
  • BR 915
People Online
Seni Jaya Logo
Brochure
Download
Our PackageContact Us