Please login to use this feature. You can use this feature to add the product to your favourite list.
Close
You have added this product to your favorite list. Check My Favourite
Close
You have removed this product from your favourite list.
Close
Please login to use this feature. You can use this feature to add the company to your favourites list.
Close
This company has been added successfully. Check My Favourite
Close
This company has been removed from your favourite list.
Close
Please login to use this feature. You can use this feature to add the company to your inquiry cart.
Close
This company has been added to your inquiry cart.
Close
This company has been removed from your inquiry cart.
Close
This product has been added to your inquiry cart.
Close
This product has been removed from your inquiry cart.
Close
Maximum number of Product/Company has been reached in inquiry cart.
Close
Hanna Instruments (M) Sdn Bhd
Hanna Instruments (M) Sdn Bhd 198801005697 (173054-W)
Business
Hours
Monday - Friday 8:30 AM - 5:30 PM
Saturday - Sunday Closed
We′re closed on Public Holiday
Open Closed
SSM
VISITORS

Penang,Selangor,Kuala Lumpur (KL),Sabah,Kota Kinabalu,Petaling Jaya,Sungai Nibong - Education HI99121 Direct Soil Measurement pH Portable Meter

04-Jul-2017

The HI99121 is the perfect portable pH meter for soil testing. With the HI99121 and HI12923 direct soil pre-amplified pH and temperature probe, users can test both the pH of soil directly or after preparation of a soil slurry with deionized water.

The HI12923 features a conical, rugged tip that can be directly inserted into moist or soft soil. For harder soils, the kit includes a plastic auger to perforate the ground.

  • Automatic Temperature Compensation
  • Automatic Two-Point Calibration
  • Waterproof

pH meter for direct soil measurement

Maintenance free gel filled electrode

Refillable

Turn cap to create positive head pressure allowing for more reference electrolyte to flow.
 

Maintenance free gel filled electrode


Built-In Temperature Sensor

Automatic compensation of temperature variations.

Maintenance free gel filled electrode



Amplified Electrode

Fast, stable response that is immune to electrical noise due to humidity.

Soil can be acid, neutral or alkaline, according to its pH value. Most plants prefer a pH range from 5.5 to 7.5; but some species prefer more acid or alkaline soils. Nevertheless, every plant requires a particular range of pH, for optimum growth.

pH strongly influences the availability of nutrients and the presence of microorganisms and plants in the soil. For example, fungi prefer acidic conditions whereas most bacteria, especially those supplying nutrients to the plants, have a preference for moderately acidic or slightly alkaline soils. In fact, in strongly acidic conditions, nitrogen fixing and the mineralization of vegetable residual is reduced. Plants absorb the nutrients dissolved in the soil water and the nutrient solubility depends largely on the pH value. Hence, theavailability of elements is different at different pH levels.

Each plant needs elements in different quantities and this is the reason why each plant requires a particular range of pH to optimize its growth. For example, iron, copper and manganese are not soluble in an alkaline environment. This means that plants needing these elements should theoretically be in an acidic type of soil. Nitrogen, phosphorus, potassium and sulfur, on the other hand, are readily available in a pH range close to neutrality. Furthermore, abnormal pH values, increase the concentration of toxic elements for plants. For example, in acid conditions, there can be an excess of aluminum ions in such quantities that the plant cannot tolerate. Negative effects on chemical and physical structure are also present when pH values are too far from neutral conditions (break up of aggregates, a less permeable and more compact soil).

The HI99121 meter features a large multi level LCD screen which displays both pH and temperature readings simultaneously with 0.01 pH resolution and an accuracy of ±0.02 pH. The LCD screen also has indicators for calibration status and stability, as well as on-screen tutorial messages. The HI99121 has many advanced features that are found in more expensive portable instrumentation including automatic calibration, buffer recognition,and temperature compensation. The battery percent level is displayed at start up alerting the user to the remaining battery power that is available. The supplied HI12923 is a glass body, amplified pH electrode with a built-in temperature sensor designed specifically for measuring the pH in soils.

 

Features at-a-glance

  • Automatic Temperature Compensation
  • One or two-point automatic calibration
  • BEPS - Alerts the user of low battery power that could adversely affect readings
  • Compact, heavy-duty, and waterproof
  • Battery % displayed on start-up
  • HELP feature, displays messages on LCD
Note: Use the soil auger for stony ground to prevent damaging the glass probe.
            For high accuracy and ensure the soil is wet use the HI7051M soil preparation solution. 


SKU HI99121
Product Name Direct Soil Measurement pH Portable Meter - HI99121
Quote Required Yes
pH Range -2.00 to 16.00 pH; -2.0 to 16.0 pH
pH Resolution 0.01 pH; 0.1 pH
pH Accuracy ±0.02 pH; ±0.1 pH
pH Calibration automatic, at one or two points with two sets of standard buffers (pH 4.01 / 7.01 / 10.01 or pH 4.01 / 6.86 / 9.18)
pH Temperature Compensation automatic ©.0 to 105.0 °C/23.0 to 221.0 °F
pH CAL Check (electrode diagnostics) probe condition indicator
mV Range ±825 mV (pH©\mV)
mV Resolution 1 mV
mV Accuracy ±1 mV (pH©\mV)
Temperature Range -5.0 to 105.0°C / 23.0 to 221.0°F
Temperature Resolution 0.1°C / 0.1°F
Temperature Accuracy ±0.5°C (up to 60°C); ±1.0°C (outside) / ±1°F (up to 140°F); ±2.0°F (outside)
pH Electrode HI12923 glass body, pre-amplified pH electrode for soil measurement with internal temperature sensor, quick connect DIN connector and 1 m (3.3’) cable (included)
Automatic Shut-Off user selectable
Battery Type/Life 1.5V (3) AAA / approximately 1400 hours of continuous use; auto-off after 8 minutes of non-use
IP Protection IP67
Environment 0 to 50°C (32 to 122°F); RH max 100%
Dimensions 154 x 63 x 30 mm (6.1 x 2.5 x 1.2”)
Weight 196 g (6.91 oz.)
Ordering Information HI99121 is supplied with HI12923 pH electrode, HI721319 soil auger, HI7051M soil preparation solution (230 mL), HI70004 pH 4.01 buffer solution sachet (20 mL), HI70007 pH 7.01 buffer solution sachet (20 mL), HI700663 cleaning solution sachet for inorganic soil deposits (20 mL), HI700664 cleaning solution sachet for organic soil deposits (20 mL), 100 mL plastic beaker, batteries, instructions, and a hard carrying case.

Send your message to Hanna Instruments (M) Sdn Bhd
Thank you for your inquiry!
Our Customer Support will be in touch with you shortly.
Your Name *
Your Company Name
Your Email *
Your Contact Number *
Subject *
Message *
Captcha *
Main Office

Hanna Instruments (M) Sdn Bhd 198801005697 (173054-W)
11A, Jalan PJS 11/20, Bandar Sunway, 46150 Petaling Jaya, Selangor, Malaysia.

Tel:

Email:
Website: https://www.hannamalaysia.com
Website: https://hannamalaysia.newpages.com.my/
Website: https://hannamalaysia.n.my/

Other Office

Hanna Instruments (M) Sdn Bhd (Penang)
N0. 303-2-27, Krystal Point, Jalan Sultan Azlan Shah, 11900 Sungai Nibong, Penang, Malaysia.

Tel:
Fax:
Email:

Hanna Instruments (M) Sdn Bhd (Sabah)
No. 4-1, 1st Floor, Plaza Kingfisher, Jalan Plaza Kingfisher 5, Inanam, 88450 Kota Kinabalu, Sabah, East Malaysia.

Tel:
Fax:
Email:

Browse by : Home - Classifieds - Companies - Location - Tags - Products - News & Promotion - Job Vacancy - Mobile Website - Google - SEO Results

NEWPAGES

  • US 17378
  • GB 13547
  • CA 10874
  • AU 10815
  • IE 4918
  • NZ 2739
  • IN 1396
  • RU 827
People Online
Seni Jaya Logo
Brochure
Download
Our PackageContact Us