Technical data
General Specifications | |
Sensing distance | 30…400mm |
Adjustment range | 50…400mm |
Unusable area | 0…30mm |
Standard target plate | 100mm×100mm |
Transducer frequency | About 310kHz |
Response delay | About 50ms |
Indicators/Operating means | |
LED blue | Power on |
LED yellow |
indication of the switching state Flashing:program function object detected |
LED red |
permanently red: Error Red,flashing:program function,object not detected |
Electrical specifications | |
Operating voltage U B | 10…30VDC,ripple10%ss |
No-load supply current | ≤30mA |
Input | |
Input type |
1 TEACH-IN input Operating distance A1:-U B …+1V,operating distanceA2:+6… + U B Input impedance:£¾4.7KΩ TEACH-IN programmable pulse :≥1S |
Output | |
Output type | 1 switch output E5,PNP NO/NC,programmable |
Rated operational current | 100mA,short-circuit/overload protected |
Default setting | Switching point A1:70mm Switching point A2: 800mm |
Voltage drop | ≤ 3V |
Repeat accuracy | ≤ 1% |
Switching frequency f | ≤ 8 HZ |
Range hysteresis H | 1% of the set operating distance |
Temperature influence | ± 1.5% of full-scale value |
Ambient conditions | |
Ambient temperature | -25…70¡æ(248...343K) |
Storage temperature | -40…85¡æ(233...358K) |
Mechanical specifications | |
Protection grade | IP67 |
Connection | V1 connector(M12×1),4-pin |
Material Housing | brass,nickel-plated |
Transducer |
epoxy resin/hollow glass sphere mixture; Polyurethane foam |
Weight | 25g |
Dimension
Adjusting the switching points
The ultrasonic sensor features a switch output with two teachable switching points. These are set by applying the supply voltage - U B or + U B to the TEACH-IN input. The supply voltage must be applied to the TEACH-IN input for at least 1s.LEDs indicate whether the sensor has recognised the target during the TEACH-IN procedure. Switching point A1 is taught with - U B ,A2 with +U B. Five different output functions can be set.1. Window mode, normally-open function.
2. Window mode, normally-closed function.
3. One switching point,normally-open function
4. One switching point,normally-closed function.
5. Detection of objet presence.
Switching point, Setting distance only after power on. The internal clock can assure can't be changed after 5 mins when power
on. If want to change the switching point, the user can only setting the request distance after power restart.