- Universal full range AC input
- 3rd generation ultra thin model, high efficiency, compliance to higher safety standards
- No load power consumption <0.5w for 200w below model
- Complete protection function
- Built-in EMI filter, extreme low ripple
- 100% full load burn-in test
- Working temperaure -30¡æ~+70¡æ(refer to derating curve)
- Conform to EN60950 GB4943 UL60950 Safety standards
- Conform to GB9254 EN55022 Class B, EMC standards
Industrial control, security, communication, household appliances, LED lighting etc.fields
AC input voltage range | 90~132VAC/180~264VAC 47~63Hz or 240~373VDC |
Over load protection | 110~140% hiccup mode, auto-recovery |
Over-voltage protection | 115~135% cut off the output, restart |
Over-temp protection | TSW1>=110¡æ±10¡æcut off the output, auto-recovery |
Withstand voltage |
I/P-O/P:3KvAC 1 minute I/P-FG:2KvAC 1 minute O/P-FG:0.5KVAC 1 minute |
Working temperature | -30¡æ~+70¡æ, 20%~90%RH |
Weight/packing | 0.66kg/20pcs/14.2kg/0.024m³/0.85CUFT |
Model | Output | Error | Range | Efficiency |
LRS-200-5 | 5v, 0-40a | ±3% | 150mV | 85% |
LRS-200-12 | 12v, 0-17a | ±2% | 150mV | 87% |
LRS-200-24 | 24v, 0-8.8a | ±1% | 150mV | 89% |