Position control for doors / casings on hazardous machinery
Contactless coded electronic sensor
Total safety management with an AWAX controller
Low cost solution for multi-access applications
Level of performance with AWAX controller: up to PL = e
Safety category: up to 4 with an AWAX controller
- Time before dangerous failure: MTTFd = 420 years
- Max. activation distance: 9 mm, 1 mm hysteresis
- Safety contacts/diagnostics: 2 x NO 0.4A max / 24V redundant and
- 1 x 250mA PNP contact
- Detection encoding: mono-code inviolable
- Indicator: LED indicates code recognition
- Reset: automatic
- Attachment: 4 tamper-proof M3 screws (optional ref: BH3)
- Mounting position: 2 (double wall brackets)
- Material: PA6 or INOX 316L mirror polished (ref. + OX)
- Electrical Connection: 3, 6, 12m cable (UL2464 PVC) or 50cm cord with M12 connector (UL20549 PUR) (ref. + MKT)
- Water resistance: IP 68
- Temperature: -20°C to +60°C
- Marking: pad printing + serial no. for traceability