Please login to use this feature. You can use this feature to add the product to your favourite list.
Close
You have added this product to your favorite list. Check My Favourite
Close
You have removed this product from your favourite list.
Close
Please login to use this feature. You can use this feature to add the company to your favourites list.
Close
This company has been added successfully. Check My Favourite
Close
This company has been removed from your favourite list.
Close
Please login to use this feature. You can use this feature to add the company to your inquiry cart.
Close
This company has been added to your inquiry cart.
Close
This company has been removed from your inquiry cart.
Close
This product has been added to your inquiry cart.
Close
This product has been removed from your inquiry cart.
Close
Maximum number of Product/Company has been reached in inquiry cart.
Close
Pacific Radio (M) Sdn Bhd
Pacific Radio (M) Sdn Bhd 16370-U

11-Aug-2015

Fluke 113 Utility Multimeter Fluke 113 Utility Multimeter

Tags:
-
Product Viewed 270
Specifications
VCHEK 1,2,3
Range  6.000 V
   60.00 V
   600.0 V
Resolution  0.001 V
   0.01 V
   0.1 V
Accuracy  DC, 45 to 500 Hz:2.0 % + 3
   500 Hz to 1 kHz: 4.0 % + 3
Diode test 4
Range  2.000 V
Resolution  0.001 V
Accuracy  2.0 % + 3
Continuity4
Accuracy  Beeper on < 20 Ω, off > 250 Ω; detects opens or shorts of 500 μs or longer
4
Range  600.0 Ω
   6.000 kΩ
   60.00 kΩ
Resolution  0.1 Ω
   0.001 kΩ
   0.01 kΩ
Accuracy  0.9 % + 2
   0.9 % + 1
   0.9 % + 1
Capacitance4
Range  1000 nF
   10.00 μF
   100.0 μF
   9999 μF
Resolution  1 nF
   0.01 μF
   0.1 μF
   1 μF
Accuracy  1.9 % + 2
   1.9 % + 2
   1.9 % + 2
   100 μF - 1000 μF: 1.9 % + 2
   > 1000 μF: 5 % + 20

Notes:
1 All VChek voltage ranges are specified from 60 counts to 100 % of range. Because inputs below 60 counts are not specified, it is possible and normal for this and other True-RMS meters to display non-zero readings when the test leads are disconnected from a circuit or are shorted together.
2 Crest factor of ≤ 3 at 4000 counts, decreasing linearly to 1.5 at full scale.
3 Minimum measureable input in VCHEK autorange is 3 V dc. For measurements below 3 V dc, push Range button twice to get to 6 V dc manual range.
4 After measuring voltage, a wait time of 1 minute is required to maintain accuracy of ohms, capacitance, diode test, and continuity.

 

Specifications
Maximum voltage between any terminal and earth ground
   600 V
Display
   3 3/4-digits, 6000 counts, updates 4/sec
Operating temperature
   -10 °C to 50 °C (14 °F to 122 °F)
Storage temperature
   -40 °C to 60 °C (-22 °F to 140 °F)
Temperature coefficient
   0.1 x (specified accuracy)/°C (< 18 °C or > 28 °C)
Operating altitude
   2,000 m
Storage altitude
   10,000 m
Relative humidity
   95 % to 30 °C
   75 % to 40 °C
   45 % to 50 °C
Battery type
   9 Volt Alkaline, ANSI 1604A / IEC 6F22
Battery life
   Alkaline: 300 hours typical, without backlight
Shock
   1 Meter drop per IEC 61010-1-2001
Vibration
   Per MIL-PRF-28800 for Class 2 instrument
Size (HxWxL)
   167.1 mm X 85.1 mm X 46.0 mm (6.58 in X 3.35 in X 1.81 in)
Weight
   13.0 oz (404 g)
Safety
   Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 No 61010-1-04, UL 61010-1 (2004) and IEC/EN 61010-1 2nd Edition for measurement Category IV, 600 V, Pollution Degree 2, EMC EN61326-1
EMI regulations
   Complies with FCC Part 15, Class B

 

Specifications
VCHEK
Input Impedance (Nominal)  ~3 kΩ < 300 pF
VCHEK
Common Mode Rejection Ratio (1 kΩ Unbalanced)  > 60 dB at dc, 50 or 60 Hz
Ω
Open Circuit Test Voltage  < 2.7 V dc
Full Scale Voltage  < 0.7 V dc
Diode test
Open Circuit Test Voltage  < 2.7 V dc
Full Scale Voltage  2.000 V dc
Short Circuit Current  < 350 μA
Diode test
Short Circuit Current  < 1.0 mA
 

Model Name Description
Fluke 113 Utility Multimeter

Accessory Kits
TLK-220 US TLK-220 US SureGrip Industrial Test Lead

Cases and Holsters
C35 C35 Soft Carrying Case
C50 C50 Meter Case
TPAK

Fluke TPAK ToolPak™ Magnetic Meter Hanger Kit includes:

  • 9 inch hook and loop strap
  • Universal hanger clip
  • Hook hanger for non magnetic surfaces
  • Strong magnet

Test Leads
TL223 TL223 Electrical Test Lead Set
 

 

Send your message to Pacific Radio (M) Sdn Bhd
Thank you for your inquiry!
Our Customer Support will be in touch with you shortly.
Your Name *
Your Company Name
Your Email *
Your Contact Number *
Subject *
Message *
Captcha *
Main Office

Pacific Radio (M) Sdn Bhd 16370-U
80, Jalan Pasar, Pudu, 55100 Kuala Lumpur, Malaysia.

Tel:
Fax:

Email:
Website: http://www.pacificradio.com.my

Other Office

Pacific Electronics (S) Pte Ltd (Head Office)
1 Rochor Canal Road, #01-10/11/12, Sim Lim Square, Singapore 188504.

Tel:
Fax:
Email:

Browse by : Home - Classifieds - Companies - Location - Tags - Products - News & Promotion - Job Vacancy - Mobile Website - Google - SEO Results

NEWPAGES

  • US 15704
  • GB 11402
  • CA 8725
  • AU 5345
  • IE 2516
  • BR 1507
  • NZ 927
  • SG 900
People Online
Seni Jaya Logo
Brochure
Download
Our PackageContact Us