Key Features
| Multiple RF testing function
| Analog standard communicaiton testing
| Auto signal testing and auto signal software
| Build-in attenuator with high power
| Optional frequency-hopping testing
| Optional dual-channel oscilloscope
| Optional digital standard communicaiton testing
S5104 Series Radio Communications Test Set, which is a multifunctional and portable model based on software radio architecture, integrates plentiful functions, like frequency-hopping signal generation and analysis, vector signal generation and demodulation analysis, analog modulation signal generation and demodulation analysis, audio signal generation and analysis, audio oscilloscope, automatic testing and so on. The tester is capable of major performance testes on transmit and receiving of radio communication equipment, measurement and analysis on feature parameters of RF, modulation, audio, and digit etc. Wide applications of the tester cover R&D, production, verification, maintenance and repair, and testing on radio communication equipment, including short-wave/ultra short-wave radio stations, data link systems, communication and surveillance satellites, radio relay equipment. Military mobile carriers with radio communication terminals like communication vehicles, surveillance vehicles, vessels and ships, as well as external field tests can use this tester conveniently.
Main Functions
Auto Testing Functions of Radio Communication Equipment
S5104 series radio communications tester can create and edit models, parameters and qualified specification limits of DUT. Choose your DUT and connect testing cable, the comprehensive tester will automatically conduct the testing. It controls transmit and receiving of the DUT by PTT. When the DUT needs setup or the cable needs being changed, the tester will automatically halt the testing and indicate further operation. The testing goes on after the operation is finished. Qualified and unqualified items will be listed directly. Other functions, like storage, viewing, comparison and remote readout, are also available.
Transmitter Testing
S5104 series radio communications tester can conduct simultaneous tests on various performance specifications of transmitters, like signal power, frequency error, signal modulation characteristics, demodulation audio, and so on. Audio signals of transmitters can be provided and single/double tones are available for your choice. It can simulate pilot signals.
Receiver Testing
S5104 series radio communications tester is able to send out FM, AM and SSB RF signals; analyze audio demodulation of the receiver; measures accurately audio frequency, voltage, distortion degree, SINAD and SNR.
Function As RF Signal Generator
Analog modulation of FM, AM, SSB etc and digital modulation of BPSK, QPSK, 8PSK, GMSK,16QAM and so on can all be output. The max. symbol rate of digital modulation is 5MHz. The tester upholds generation of 60MHz transient bandwidth frequency-hopping signals.
RF Receiving And Demodulation
S5104 series radio communications tester is capable of demodulation and analysis of analog modulation like FM, AM, SSB etc and that of digital modulation signals including BPSK, QPSK, 8PSK, GMSK and 16QAM. Demodulation parameters and waveforms can be output. The max. demodulation bandwidth of analog modulation signals reaches 300kHz and the max. symbol rate of digital modulation and signal demodulation is 5MHz. Narrow band power measurement is available.
Sweep Spectrum Analysis
S5104 series radio communications tester has wide frequency band, high resolution, high sensitivity, big dynamic range and other characteristics.
Frequency-hopping Signal Analysis
The max. transient analysis bandwidth of frequency-hopping signals is 60MHz. The display types are three-dimensional spectrum graph, time-frequency graph and time-amplitude graph. The tester can capture, store and analyze frequency-hopping signals. You can view spectrum and modulation domain graphs at any time. When modulation domain measurement is in progress, it is capable of accumulation and display of frequency points within any timeframes. Frequency-hopping points can be observed directly. Pulse signals and transient signals can also be measured.
Audio Signal Generation
Single and double tones are available for your choice. The max. output level reaches 7Vrms.
Audio Signal Analysis
Audio filter is optional. The max. input level is up to 30Vrms. The tester supports measurements on frequency, level, distortion degree, SINAD and SNR, as well as audio waveform display.
Simultaneous Operation on Multiple Windows
Support simultaneous operation of 4 windows at most, each window can be enlarged individually.
Typical Applications
S5104 series radio communications test set is extensively employed due to the powerful functions and performances, which is used for R&D, repair, maintenance and testing of communication equipment.
Technical Specifications
RF Signal Generation | |
Frequency Range | S5104B: 1MHz - 1.05GHz |
S5104C: 1MHz - 3GHz | |
Frequency Resolution | 1Hz |
Output Level Range |
GEN: -120dBm to +5dBm(max. modulation 0dBm) |
T/R interface: -130dBm to -35dBm |
|
Level Resolution | 0.1dB |
Level Accuracy |
±1.5dB(>-110dBm), ±2.0dB(<-110dBm) |
SSB Phase Noise | f<=1.05GHz: -93dBc/Hz @20kHz |
f>1.05GHz: -90dBc/Hz @20kHz | |
Harmonic |
Better than -25dBc (>1MHz, <0dBm) |
Non-harmonic |
Better than -35dBc (>1MHz, +5dBm output) |
Internal Analog Modulation Source |
Sine, square wave, triangle, saw-tooth, dual-tone (analog pilot) |
Broadband Power Measurement | |
Frequency Range | S5104B: 400kHz - 1.05GHz |
S5104C: 400kHz - 3GHz | |
Measurement Range |
ANT interface: 0.1mW - 100mW |
T/R interface: 100mW - 150W | |
Measurement Accuracy |
15% (<=120W, CW or frequency modulation) |
Narrow Band Power Measurement | |
Frequency Range | S5104B: 300kHz - 1.05GHz (low frequency depends on small IF bandwidth) |
S5104C: 300kHz - 3GHz (low frequency depends on small IF bandwidth) | |
Measurement Range |
ANT interface: +10dBm to -80dBm |
T/R interface: +51dBm to -40dBm | |
Measurement Accuracy |
±2dB |
Receiving Bandwidth |
6.25, 8.33, 10, 12.5, 25, 30, 100, 300kHz |
Frequency Error Meter | |
Frequency Range | S5104B: 300kHz - 1.05GHz (low frequency depends on small IF bandwidth) |
S5104C: 300kHz - 3GHz (low frequency depends on small IF bandwidth) | |
Accuracy |
Frequency standards ±1Hz |
Audio Signal Generation | |
Waveform |
Sine, square wave, triangle, saw-tooth |
Signal Type |
Single-tone, dual-tone |
Frequency |
20Hz - 20kHz (sine), 20Hz - 4kHz (square wave, triangle, saw-tooth) |
Frequency Resolution |
0.1Hz |
Level Range |
1mV - 7Vrms (10kΩ load) |
Level Accuracy |
±5% (10kΩ load >=10mVrms) |
Audio Signal Analysis | |
Input Impedance |
150Ω, 600Ω, high impedance |
Max. input Level |
30Vrms (high impedance) |
Audio Filter | Low-pass: 300Hz, 5kHz, 15kHz, 20kHz |
Band-pass: 0.3-3.4kHz, 0.3-5kHz, 0.3-15kHz, 0.3-20kHz | |
Sweep Spectrum Analyzer | |
Frequency Range | S5104B: 100kHz - 1.05GHz |
S5104C: 100kHz - 3GHz | |
Sweep Width |
0Hz - whole frequency bands |
Level Precision |
±1.5dB |
Min. DANL | ANT interface: better than -125dBm |
T/R interface: better than -75dBm | |
Resolution Bandwidth |
30Hz - 3MHz (1-3 stepping) |
Demodulation And Analysis of Analog Modulation Signals |
|
Frequency Range | S5104B: 300kHz - 1.05GHz (low frequency depends on small IF bandwidth) |
S5104C: 300kHz - 3GHz (low frequency depends on small IF bandwidth) | |
Signal Format |
FM, AM, SSB |
Demodulation |
6.25, 8.33, 10, 12.5, 25, 30, 100, 300kHz |
Demodulation Audio Filter | Low-pass: 300Hz, 5kHz, 15kHz, 20kHz |
Band-pass: 0.3-3.4kHz, 0.3-5kHz, 0.3-15kHz, 0.3-20kHz | |
Frequency Range of Demodulation Counter | 20Hz - 20kHz |
Demodulation Counter Resolution | 0.1Hz |
Sensitivity |
<-100dBm (10dB SINAD, ANT interface) |
Demodulation And Analysis of Vector Signals (Option) | |
Frequency Range | S5104B: 300kHz - 1.05GHz (low frequency depends on small IF bandwidth) |
S5104C: 300kHz - 3GHz (low frequency depends on small IF bandwidth) | |
Signal Format |
GMSK, BPSK, QPSK, 8PSK, 16QAM |
Demodulation Bandwidth | 10kHz - 10MHz |
Max. Symbol Rate | 5MHz |
Frequency-hopping Signal Analysis (option) | |
Filter |
RC, RRC, GAUSS |
Transient Bandwidth |
60MHz, 30MHz, 15MHz, 7.5MHz, 3.75MHz, 1.875MHz |
Capture Storage Depth |
8GB |
Analysis Domain |
Time-frequency (modulation domain), time-amplitude, time-spectrum (waterfall chart), spectrum at random time |
Min. Time Resolution | 10ns |
Dual-channel Oscilloscope | |
Frequency Range | DC-4MHz |
Vertical Scale |
10mV - 10V/mark (1, 2, 5 stepping) |
Horizontal Scale |
1us - 1s/mark (1, 2, 5 stepping) |
Coupling Type | DC, AC |
Input Impedance |
1MΩ |
Digital SequenceGeneration And Bit Error Rate Measurement(option) | |
Digital Format |
PN3, PN5, PN9, PN11 |
Baud Rate |
300bps - 1Mbps (BPSK, GMSK, 2FSK, 2ASK) |
Bit Error Rate Measurement Range | 0.1 - 0.000001 |
Internal Time-base |
Frequency: 10MHz; Aging rate: 1×10-7/year;Temperature stability: ±0.05ppm (0 - 50°C) |
More specifications in the datasheet.
General Information
Dimensions (W×H×D) |
426×222×180mm (without handles and auxiliaries) |
Weight | <= 12kg |
Working Temperature |
0°C to +50°C |
Storage Temperature | -40°C to +70°C |
Power Supply |
Internal AC: 220V±10%, frequency 50Hz±5%; External DC: 24V±2V (16V is Acceptable); Built-in and rechargeable battery: >=11000mAh (option) |
Consumption | <100W |
Cooling Type |
Internal air cooling |
Interface |
RF: GEN interface(TNC), T/R interface(type N), ANT interface(TNC) BNC: audio input, audio output, oscilloscope input etc Others: network port (support remote control), 26-core testing bus interface, USB-host interface etc. |
Standard Package
No. | Item | Qty. |
1 | Main machine | 1 PC |
2 | User manual | 1 PC |
3 |
Tri-core 220VAC power cord |
1 PC |
4 |
N-BNC adapter |
1 PC |
5 |
N-SMA adapter |
1 PC |
6 |
TNC-SMA adapter |
1 PC |
Options
Option No. | Item |
S5104-H01 |
Built-in lithium battery |
S5104-S01 |
Software for vector signal generation and bit error rate measurement |
S5104-S02 |
Software for vector signal demodulation and analysis |
S5104-S03 |
Software for frequency-hopping signal generation
|
S5104-S04 |
Software for frequency-hopping signal analysis |
S5104-S05 |
Software for dual-channel oscilloscope |