Brand: Honda
Model: HUS-3
Description:
-
The rechargeable battery allows for use in any location.
(Usable time: 10 hours). - The readings can be checked by simply inserting the tip of the sensor into the liquid (display: mV).
- Supports a wide range of frequencies from 10 kHz to 5 MHz.
- Comes with a special case for easy carrying and storage.
- This unit cannot be calibrated.
- This equipment provides relative values, and not absolute values.
- This equipment could fail if it is set up to perform continuous operation.
Applications:
- For adjustment, inspection and quality control of ultrasonic cleaners manufacturers
- For laboratory experiments
-
By placing the sensor in the tank (or running water) of an ultrasonic cleaner, the ultrasonic intensity generated inside the tank is displayed in mV.
(The displayed value is a relative value.)
Technical Specification:
Model | HUS-3 |
Frequency characteristics | 10kHz¡«5MHz |
Power |
Dedicated lithium battery: HBT-001(JP01) DC14.8V 1.5W |
Charger | Dedicated battery charger: BT-024 (JA01) |
Signal Input | 1 designated probe |
Measuring range | 10 / 50 / 100 / 500 mV |
External Dimensions WxDxHmm |
179×132×55 ¡¡(Not including protrusions) |
Weight | 640g £¨When lithium battery is inserted£© |
Meter indication value | Probe detection voltage (mV) rms relative value |
- Accessories:
- AC adapter for charging
- Dedicated lithium-ion battery (HBP-001)
- Operating temperature range: 5 to 40°C
- AC adapter for charging: Power input 100-240V 50/60Hz
- Optional accessories: Point sensing cover (PS01), battery (HBP-001), chargin stand (JS01)
Sensor - Quartz type
Model | HUS-5¡¡SPS | HUS-5 SPL |
Shape | Straight | L-shape |
Material | Quartz glass | |
Over-all length | 340mm | 260mm £¨L section 80mm) |
Weight | 80g | |
Incompatible liquids | Heated strong alkalis, thermal phosphoric acid, hydrofluoric acid | |
Liquid temperature range | 0¡«70¡æ | |
Cable length | 1.5m |
Sensors - SUS Type
Model | HUS-5¡¡SUS | HUS-5 SUL |
Shape | Straight | L-shape |
Material | SUS316L | |
Over-all length | 340mm | 260mm £¨L section 80mm) |
Weight | 140g | |
Incompatible liquids | All acids | |
Liquid temperature range | 0¡«70¡æ | |
Cable length | 1.5m |
- This unit cannot be calibrated.
- This equipment provides relative values, and not absolute values.
- This equipment could fail if it is set up to perform continuous operation.
Optional:
Point sensing cover (PS01)

- A cover for pinpointing the area to be measured.
- This is for straight type only.