The compact design of Single stage regulator’s makes convenient connection with gas cylinder. The outlet connection can be selected either hose or PT type which enable to connect with hose or pipe. Also the internal relief valve is equipped in low pressure type for the safety.
Application
Hwa Young’s single system regulator is optimized for single system of LP gas system. Generally, it can be used with connecting directly to the low capacity gas cylinder and provide reduced pressure properly. The application is for cooking at residence and low capacity heating and outdoor appliances with convenient at all time.
Hwa Young’s single system regulator is designed for satisfied with quick response and proper pressure to supply of gas.
The regulator works with inlet pressure (0.07MPa ~ 1.56MPa) and outlet pressure range(2.3~33kPa). If the pressure is excessive than the setting pressure, the equipped internal relief valve operates to maintain the pressure for safety.
Feature
- The loose stopper can avoid intentional opening.
- The diaphragm which is certified for KS with its material NBR can precisely measure the pressure to high accuracy of supply of setting fl ow rate of gas and it is possible for long lasting use.
- Internal relief is equipped for safety by release of the gas to the atmosphere to prevent explosion. (Low Pressure)
- The aluminum die casting body makes very neat exterior by precise machining. The corrosion resistance body makes possible for semi permanently use.
- The direct operation system and optimized design for gas flow enable quick response to variation of gas flow.
1. Check if the gas regulator and the cylinder’s specifi cation is correctly matched.
2. Refer to Fig. 1 and connect the cylinder and regulator by tightening handle.
3. Check if the connection end of pipe is clean and apply Tefl on piping tape or sealant for connection like Fig. 2-1.
3. Connect the pigtail hose with regulator with referring to Fig. 2-2 and use handle for tightening.
Fig 1. Cylinder
Fig 2-1. Pipe Conn.
Fig 2-2. Hose Conn.
Low Pressure Type | |
Inlet Pressure Range (P1) : | 0.07~1.56 MPa |
Setting Outlet Pressure (P2) : | 2.8 kPa |
Outlet pressure Range : | 2.8±0.5 kPa |
Capacity : | 4 kg/h |
Internal Relief Working Pressure : | 7.0±1.4 kPa |
Inlet Connection Size : | Pol Handle L.H W22.5*14T |
Outlet Connection Size : | Hose end |
Application : | Household |