Robust Insulation Tester/ Electrical resistance / Earthing resistance / Loop impedance / Voltage measurement / Low resistance measurement / RCD test
The measuring range for low-resistance measurement with the installation tester is in the range of 0 - 2000 Ω with a resolution of 0.001 - 1 Ω. Probably the most important measurement of the installation tester is the measurement of insulation resistance. Electrical cables are placed under voltage during the insulation measurement in order to detect fault currents, which generate material migration or heat. In most cases, these current faults are so minimal that they are not detected by protective devices and in the worst case they can lead to a fire. The installation tester can carry out installation measurement with a test voltage of 125V, 250V, 500V or 1000V.
The load current is in each case 1 mA. The installation tester is independent of the mains supply. In order to bring all systems and circuits of a power supply system to a common potential (ground reference or potential reference) and to protect against short-circuit currents and overvoltages, the earthing resistor should be as low-impedance as possible. With a measuring range of 0 ... 2000 Ω with a resolution of 0.01 ... 1 Ω, the installation tester DT-6650 offers all the prerequisites for a meaningful measurement of the grounding resistance.
Schuko socket connection / Direct acceptance of all connections via laboratory plugs
The EVSE adapter is specially designed for this application and already comes with a variety of functions. For example, all lines leaving the charging station are output individually via laboratory plugs. Thus, all lines can be tapped via the EVSE adapter. This allows the charging station to be checked for insulation with the help of the EVSE adapter. The EVSE adapter has a shock-proof plug connection. The RCD tester can be used to check the residual current device.
A charging cable not only contains the supply lines for charging an electric vehicle, but also two interfaces. The electric vehicle communicates with the charging station via the CP line (Control Pilot) and communicates the current status of the electric vehicle. The PP line (Proximity Plug) is used for communication between the connected charging cable and the charging station. The charging cable can thus tell the charging station how many amps it may be loaded with. To test both functions, the EVSE adapter is equipped with corresponding simulators.
- 3.5'' colour TFT LCD display
- Loop resistance L-N, L-PE and N-PE
- Adjustable FI test current
- SD card and bluetooth
- Dual display
- Good / bad FI test
- Low Ohm measurement
- Up to 1000 V terminal voltage
- Transport bag included in delivery
- Direct connection for wallboxes
- Adapter with type 1 and type 2 charging plugs
- PE conductor test
- Integrated Schuko socket
Delivery scope
EVSE Measuring Device PCE-EVSE-KIT2
1 x EVSE Adapter PCE-EVSE 300
1 x Installation Tester PCE-ITE 50
1 x Charging cable plug type 1
1 x Charging cable plug type 2
1 x Transport bag
1 x Instruction manual
1 x Test leads
1 x Transport case