Please login to use this feature. You can use this feature to add the product to your favourite list.
Close
You have added this product to your favorite list. Check My Favourite
Close
You have removed this product from your favourite list.
Close
Please login to use this feature. You can use this feature to add the company to your favourites list.
Close
This company has been added successfully. Check My Favourite
Close
This company has been removed from your favourite list.
Close
Please login to use this feature. You can use this feature to add the company to your inquiry cart.
Close
This company has been added to your inquiry cart.
Close
This company has been removed from your inquiry cart.
Close
This product has been added to your inquiry cart.
Close
This product has been removed from your inquiry cart.
Close
Maximum number of Product/Company has been reached in inquiry cart.
Close
Hanna Instruments (M) Sdn Bhd
Hanna Instruments (M) Sdn Bhd 198801005697 (173054-W)
Waktu
Pejabat
Isnin - Jumaat 8:30 AM - 5:30 PM
Sabtu - Ahad Closed
We′re closed on Public Holiday
Open Closed
SSM
PENGUNJUNG

Penang,Selangor,Kuala Lumpur (KL),Sabah,Kota Kinabalu,Petaling Jaya,Sungai Nibong - HI96803 Digital Refractometer for % Glucose by Weight Analysis

11-Jul-2017

The HI96803 is a rugged, portable digital refractometer for food products designed to report the content of aqueous solutions containing sugar as % glucose by weight (% w/w). The HI96803 report the results with an accuracy of ±0.2%. The operation of the meter is simplified with only two buttons: one button is to calibrate with distilled or deionized water and the other to take a measurement. All readings are automatically compensated for temperature variations according to the ICUMSA Methods Book standard and displayed within a 1.5 second response time. The sealed flint glass prism and stainless steel well are easy to clean. Just wipe with a soft cloth in preparation for the next sample.

  • Sample size as small as 2 metric drops (100 μl)
  • Sealed stainless steel well with high-grade optical prism made of flint glass
  • Fast 1.5 second response time for temperature compensated readings

The HI96803 portable refractometer converts the refractive index of a food sample to % glucose by weight. This conversion is based on the tables found in the ICUMSA Methods Book (International Commission for Uniform Methods of Sugar Analysis) that documents the changes in refractive index with temperature for a percent by weight glucose solution. The HI96803 is ideal for the analysis of fruits, energy drinks, puddings, soy milk, juices, jam, marmalade, honey, soups, jelly, tofu and condiments. The HI96803 is an easy to use tool for measuring sugar in food samples in the field or in the lab.

  • Designed for food sugar analysis
  • Temperature Compensation algorithms based on glucose solution
  • 0 to 85% glucose by weight range with an accuracy of ± 0.2%

Making a % Standard Glucose Solution

To make a glucose Solution, follow the procedure below:

  • Place container (such as a glass vial or dropper bottle that has a cover) on an analytical balance.
  • Tare the balance.
  • Weigh out X grams of high purity glucose (CAS #: 50-99-7) directly into a beaker
  • Add distilled or deionized water to the beaker so the total weight of the solution is 100g.
  • Note: Solutions above 60% may need to be vigorously stirred or shaken and heated in a water bath to roughly 40°C (104°F). Remove solution when fructose has dissolved and allow to cool before use.
Example to prepare as 25% glucose solution:
Glucose % (g/100g) Glucose (g) Water (g) Total (g)
25 25.000 75.000 100.000

 

refractive index

 

Refractive Index

The HI96803 takes measurements based on a sample’s refractive index. Refractive index is a measurement of how light behaves as it passes through the sample. Depending on the sample’s composition, light will refract and reflect differently. By measuring this activity with a linear image sensor, the sample’s refractive index can be assessed and used to determine its physical properties such as concentration and density. In addition to the linear image sensor, the HI96803 uses an LED light, prism and lens to make measurement possible.

Variations in temperature will affect the density of a solution based on the compound that is present. In digital refractometry the use of temperature compensation is necessary for accurate results. The HI96803 contains a built-in temperature sensor and is programmed with temperature compensation algorithms in accordance with the ICUMSA Methods Book for a percent by weight sucrose solution.

 

Features at-a-glance:


One-point calibration
  • Calibrate with distilled or deionized water

Small sample size
  • Sample size can be as small as 2 metric drops (100 μl)

Automatic Temperature Compensation (ATC)
  • Samples automatically compensated for temperature variations

Quick, accurate results
  • Readings are displayed in approximately 1.5 seconds

Dual-level LCD
  • The dual-level LCD displays measurement and temperature readings simultaneously

 

Stainless steel sample well
  • Easy to clean and corrosion-resistant

Battery indicators
  • Battery percent level remaining at startup and low battery indicator

Automatic shut-off
  • To conserve battery life the meter shuts off automatically after three minutes of non-use

Stainless steel sample well
  • Easy to clean and corrosion-resistant

IP65 water resistant protection
  • Water resistant ABS plastic casing designed to perform under laboratory and field conditions.

SKU HI96803
Product Name Digital Refractometer for % Glucose by Weight Analysis - HI96803
Quote Required Yes
Sugar Content Range 0 to 85% mass (% w/w glucose)
Sugar Content Resolution 0.1% mass
Sugar Content Accuracy ±0.2% mass
Temperature Range 0 to 80°C (32 to 176°F)
Temperature Resolution 0.1°C (0.1°F)
Temperature Accuracy ±0.3 °C (±0.5 °F)
Temperature Compensation automatic between 10 and 40°C (50 to 104°F)
Automatic Shut-Off after three minutes of inactivity
Battery Type/Life 9V / approximately 5000 readings
Dimensions 192 x 102 x 67 mm (7.6 x 4.01 x 2.6”)
Weight 420 g (14.8 oz.)
Refractometer Light Source yellow LED
Minimum Sample Volume 100 μL (to cover prism totally)
Sample Cell stainless steel ring and flint glass prism
Measurement Time approximately 1.5 seconds
Ordering Information HI96803 is supplied with battery and instruction manual
Notes Enclosure Rating

Hantar mesej anda ke Hanna Instruments (M) Sdn Bhd
Terima kasih untuk pertanyaan anda!
Perkhidmatan pelanggan kami akan menghubungi anda tidak lama lagi.
Nama Anda *
Nama Syarikat Anda
Emel Anda *
Nombor Telefon Anda *
Tajuk *
Mesej *
Captcha *
Pejabat Utama

Hanna Instruments (M) Sdn Bhd 198801005697 (173054-W)
11A, Jalan PJS 11/20, Bandar Sunway, 46150 Petaling Jaya, Selangor, Malaysia.

Tel:

Emel:
Laman Web: https://www.hannamalaysia.com
Laman Web: https://hannamalaysia.newpages.com.my/
Laman Web: https://hannamalaysia.n.my/

Pejabat Lain

Hanna Instruments (M) Sdn Bhd (Penang)
N0. 303-2-27, Krystal Point, Jalan Sultan Azlan Shah, 11900 Sungai Nibong, Penang, Malaysia.

Tel:
Fax:
Emel:

Hanna Instruments (M) Sdn Bhd (Sabah)
No. 4-1, 1st Floor, Plaza Kingfisher, Jalan Plaza Kingfisher 5, Inanam, 88450 Kota Kinabalu, Sabah, East Malaysia.

Tel:
Fax:
Emel:

Melayari Melalui : Laman Utama - Klasifikasi - Syarikat - Tempat - Tag - Produk - Berita Baru dan Promosi - Jawatan Kosong - Laman Web Mudah Alih - Google - Keputusan SEO

NEWPAGES

  • US 12037
  • GB 9311
  • CA 7932
  • AU 7608
  • IE 3694
  • NZ 3195
  • IN 911
  • MY 871
Orang dalam talian
Seni Jaya Logo
Brochure
Download
Our PackageContact Us