Please login to use this feature. You can use this feature to add the product to your favourite list.
Close
You have added this product to your favorite list. Check My Favourite
Close
You have removed this product from your favourite list.
Close
Please login to use this feature. You can use this feature to add the company to your favourites list.
Close
This company has been added successfully. Check My Favourite
Close
This company has been removed from your favourite list.
Close
Please login to use this feature. You can use this feature to add the company to your inquiry cart.
Close
This company has been added to your inquiry cart.
Close
This company has been removed from your inquiry cart.
Close
This product has been added to your inquiry cart.
Close
This product has been removed from your inquiry cart.
Close
Maximum number of Product/Company has been reached in inquiry cart.
Close
Hanna Instruments (M) Sdn Bhd
Hanna Instruments (M) Sdn Bhd 198801005697 (173054-W)
Waktu
Pejabat
Isnin - Jumaat 8:30 AM - 5:30 PM
Sabtu - Ahad Closed
We′re closed on Public Holiday
Open Closed
SSM
PENGUNJUNG

04-Jul-2017

The Hanna Instruments HI99171 is a durable, waterproof, and portable pH and temperature meter designed specifically for leather and paper analysis. Automatic calibration is performed at one or two points with two sets of buffers. All calibration and measurement readings are automatically compensated for temperature variations.

The HI99171 uses the HI14143 glass body, amplified pH electrode that offers numerous features that improve pH testing for surface measurements. The split-level LCD displays both pH and temperature readings, along with indicators for reading stability, battery percentage, and calibration instructions.

  • Automatic Temperature Compensation
  • Automatic Two-Point Calibration
  • Waterproof

pH measurement of paper, leather, and other surfaces are important during manufacturing and final product stages. In the paper industry, a pH measurement indicates the chemical stability and permanence of a paper. It is desirable to manufacture paper that has a neutral or slightly basic pH to aid in the preservation of important documents, publications, and artworks. An acid-free or alkaline paper is able to absorb damaging acid compounds that are naturally formed through aging.

pH of paper and cartons is also important in the food industry. Food packaging often incorporates antimicrobial agents to inhibit microbial activity during distribution and storage conditions. The activity of antimicrobial agents can quickly change with a variation in pH. pH compatibility tests consider food composition, chemistry of the antimicrobial agents used, and packaging material.

In leather making, tanning is one of the most chemically complex steps. Generally, tanning creates a leather product that is more breathable, flexible, and suitable for use in handbags, luggage, garments, and a variety of commercial items. Tanning is performed by a vegetable method or chrome method; chrome-tanned leather requires the addition of chromium salts and a basic component to raise the pH. The pH of the liquors used in the leather making process and the pH of the final leather product directly affect characteristics such as firmness, heat resistance, and durability.

The HI99171 uses the HI14143 amplified pH electrode with glass body. This specialized electrode offers numerous features that improve surface pH testing. An integrated temperature sensor allows for temperature compensated pH measurements without the need for a separate temperature probe. The probe’s flat sensing tip provides optimal surface contact with samples.

An integral part of any pH electrode is the reference junction. The reference junction is a part of the electrode that allows for the flow of ions located in the reference cell into the sample being tested. It is vital that this flow occurs in order to complete an electrical circuit, which ultimately determines the pH value. Poor contact between the junction and sample will prevent completion of the circuit, resulting in readings that are erratic or constantly drifting.

The flat tip of the HI14143 provides optimal surface contact between the sample and the junction. The HI14143 features an open junction design which utilizes a viscolene reference electrolyte that comes into direct contact with the sample, providing accurate, stable readings.

HI1414D

Glass Body

Glass Body
The glass body of the HI14143 is chemically resistant and quick to reach thermal equilibrium, allowing for a faster, more stable response on a wide variety of surfaces.

Flat Tip

Flat Tip
The flat tip sensing bulb allows for the direct surface measurement of a sample. The versatility of this tip shape allows pH measurement of samples ranging from leather and paper to cartons.

ATC

Open Junction Reference
The open junction design consists of a solid gel interface (viscolene) between the sample and internal Ag/AgCl reference. This interface not only prevents silver from entering the sample, but also makes it impermeable to clogging, resulting in a fast response and stable reading.

ATC

Built-In Temperature Sensor
Errors in calibration and measurement are eliminated with the Automatic Temperature Compensation provided by the integrated temperature sensor.

Features at-a-glance

 

Waterproof - The HI99171 is a waterproof meter rated IP67 for immersion in up to one meter of water for 30 minutes.

Automatic Calibration - One or two-point calibration is automatic to two selectable buffer sets.

Automatic Temperature Compensation – An integrated temperature sensor allows for automatic temperature compensation of pH measurements.

Sensor Check - Using the pH©\mV range the user can check the sensor status by reading the mV reading in fresh buffers. At room temperature (25 oC/77oF) the reading should be +/- 30 mV in pH 7.01 and greater than 150 mV difference between pH 7.01 and 4.01.

Multi-Level LCD Display - The split-level LCD displays both pH and temperature readings, along with indicators for reading stability, battery percentage, and probe condition.

Probe Condition Indicator - The probe condition indicator is based on the offset and slope characteristic of the electrode. There are 5 bars ranging from all 5 indicating the probe is in excellent condition and 1 bar indicating the probe should be cleaned or replaced.

Battery Error Prevention System - The meter will automatically shut off if there isn’t enough power to obtain an accurate measurement.

Battery Life Indicator - The battery percent level is displayed at start up alerting the user to the remaining battery power that is available.

 

SKU HI99171
Product Name Leather and Paper pH Portable Meter - HI99171
Quote Required Yes
pH Range -2.00 to 16.00 pH
pH Resolution 0.01 pH
pH Accuracy ±0.02 pH
pH Calibration automatic, at one or two points with two sets of buffers (standard 4.01, 7.01,10.01 or NIST 4.01, 6.86, 9.18)
pH Temperature Compensation automatic from -5.0 to 105.0ºC (23 to 221ºF)
pH CAL Check (electrode diagnostics) probe condition indicator
pH Sensor Check yes
mV Range ±825 mV (pH©\mV)
mV Resolution 1 mV (pH©\mV)
mV Accuracy ±1 mV (pH©\mV)
Temperature Range -5.0 to 105.0°C / 23.0 to 221.0°F
Temperature Resolution 0.1°C / 0.1°F
Temperature Accuracy ±0.5°C (up to 60°C); ±1.0°C (outside) / ±1°F (up to 140°F); ±2.0°F (outside)
pH Electrode HI14143 pre-amplified pH probe with internal temperature sensor, quick connect DIN connector and 1 m (3.3’) cable (included)
Automatic Shut-Off user selectable
Battery Type/Life 1.5V (3) AAA / approximately 1400 hours of continuous use
IP Protection IP67
Environment 0 to 50°C (32 to 122°F); RH max 100%
Dimensions 154 x 63 x 30 mm (6.1 x 2.5 x 1.2”)
Weight 196 g (6.91 oz.)
Ordering Information HI99171 is supplied with HI14143 flat tipped pH/temperature probe, HI70004 pH 4.01 buffer solution sachet (20 mL), HI70007 pH 7.01 buffer solution sachet (20 mL), HI700680 electrode cleaning solution for ink stains sachets (2 x 20 mL), HI70960 conductive electrolyte solution for pH measurement (30 mL), 100 mL beaker, batteries, calibration certificates for both the meter and probe, instructions and rugged thermoformed carrying case.

Hantar mesej anda ke Hanna Instruments (M) Sdn Bhd
Terima kasih untuk pertanyaan anda!
Perkhidmatan pelanggan kami akan menghubungi anda tidak lama lagi.
Nama Anda *
Nama Syarikat Anda
Emel Anda *
Nombor Telefon Anda *
Tajuk *
Mesej *
Captcha *
Pejabat Utama

Hanna Instruments (M) Sdn Bhd 198801005697 (173054-W)
11A, Jalan PJS 11/20, Bandar Sunway, 46150 Petaling Jaya, Selangor, Malaysia.

Tel:

Emel:
Laman Web: https://www.hannamalaysia.com
Laman Web: https://hannamalaysia.newpages.com.my/
Laman Web: https://hannamalaysia.n.my/

Pejabat Lain

Hanna Instruments (M) Sdn Bhd (Penang)
N0. 303-2-27, Krystal Point, Jalan Sultan Azlan Shah, 11900 Sungai Nibong, Penang, Malaysia.

Tel:
Fax:
Emel:

Hanna Instruments (M) Sdn Bhd (Sabah)
No. 4-1, 1st Floor, Plaza Kingfisher, Jalan Plaza Kingfisher 5, Inanam, 88450 Kota Kinabalu, Sabah, East Malaysia.

Tel:
Fax:
Emel:

Melayari Melalui : Laman Utama - Klasifikasi - Syarikat - Tempat - Tag - Produk - Berita Baru dan Promosi - Jawatan Kosong - Laman Web Mudah Alih - Google - Keputusan SEO

NEWPAGES

  • US 9867
  • GB 8010
  • CA 6799
  • AU 5862
  • IE 4054
  • NZ 1665
  • SG 926
  • IN 736
Orang dalam talian
Seni Jaya Logo
Brochure
Download
Our PackageContact Us