ACOTOM PROCESS / UNIQUE TECHNOLOGY :
Electronic decoding of 2 coded and independent magnetic fields
=> You can't defraud him with a magnet.
Insensitive to external magnetic fields
=> allows the use of INOX316L housing
Can be decoded through a steel plate up to 6mm thick
=> the sensor can be protected (embedded in the machine structure)
HYGIEN DESIGN to avoid the adhesion of bacteria and facilitate cleaning :
- 316L stainless steel housing with mirror polished finish
- Rounded corners and slopes to avoid water stagnation
- Designed to have the best cleaning quality
- Silicon gasket and stainless steel nut
- Traceability by LASER engraving and mechanical punching
- Simple connection and fast serial connection with T-SPLITTER
Security level (according to ISO 13849-1) |
PLc, Cat 1 without Safety Relays (up to PLe, cat 4 with safety relay) |
Supply voltage | 20VDC at 30VDC |
Security contact | 2 potential-free NO contacts 1A/48V |
Auxiliary contact | 1 NF (PNP) |
Operating temperature | -25°C at +60°C |
Scanning range |
Sao = 6 mm (guaranteed activation distance) Sar = 8 mm (assured breaking distance) |
Materials / IP |
STAINLESS STEEL316L with LASER marking IP69K (front) - IP67 (rear and connector) |
Connecting | PUR cable (50cm) + M12/8 pin connector |
LED | Red = door open |
Diametre | M30 |