Product outline
EtherNet/IP is a registered trademark of ODVA.
FC400-EIP is a compact type indicator equipped with EtherNet/IP & USB as standard features.
Matches perfectly with every weighing applications such as hopper scale, packer scale, weighing monitor, etc.It has displayable graph in the pc software, and setup can be done easily.
High sampling rate & resolution
High-Speed A/D conversion and powerful digital processing capability of 1200 times/sec..
High display resolution of 1/100000 (max).
Application software for USB interface
With communication through USB interface, logging, graph, display, setting parameters, and calibration can be done.
High performance filter & Auto filter adjustment
With combination of low pass filter (0.1 to 300Hz) which corresponds to various vibration and moving average filter (OFF, 2 to 512) that is effective for periodic vibration, automatic searching for optimal value with accuracy and stability can be achieved.
(You can manually adjust settings too).
Lightweight and compact body to fit into limited space in a control panel
Light weight & compact body for 35mm DIN rail mount.
Dimensions : 34(W)×88(H)×91(D)mm (Projections excluded)
Weight : Approx. 230g
Various interfaces
Load cell signal level display (-2.51mV/V to 5.1mV/V)
The output signal level of load cell can be displayed in mV/V for monitor purpose.
Malfunction indicator or faulty sensor can be differentiated easily.
6 digit display
24 bit A/D convertor enables 6 digit display.
Equivalent input calibration
Theoretical calibration can be performed easily by registering the capacity and rated output of load cells.
Multipoint calibration (linearization)
Three additional points can be defined in the middle between zero and span for better linearity.
Even though the scale has poor linearity, it can be corrected to be a highly accurate scale.
Specifications
Analog section£üDisplay section£üExternal signal£üInterface£üGeneral performance£üAttachments
Analog section | |
Excitation voltage |
DC5V±5% Output current: 90mA DC2.5V±5% Output current: 45mA Ratiometric method (Up to 6 350Ω load cells can be connected in parallel) |
---|---|
Signal input range | -2.5 to 5.1mV/V |
Zero adjustment range | Automatic adjustment by digital processing -0.5 to 2.0mV/V |
Span adjustment range | Automatic adjustment by digital processing 0.01 to 3.0mV/V |
Linearization function | Up to three point multi-point calibration is possible |
Min. input sensitivity | 0.15μV/count |
Accuracy |
Non-linearity: within 0.01%FS Zero drift: 0.0002%FS/¡æ Typ Gain drift: 1ppm/¡æ Typ |
Filter |
Digital low-pass filter: 0.1 to 300 Hz Moving average filter: OFF, 2 to 512 times |
A/D converter |
Speed: 1200 times/sec. Resolution: 24bit binary |
Display section | |
Display unit | Character height 8mm, Numerical display by 7-segment green LED |
---|---|
Display value | Up to 6 digits |
Display frequency | Selectable from 3, 6, 13, 25 times/sec. |
Status display | MS, NS |
External signal | |
Output signal (5) |
Selectable/configurable Transistor’s open collector output Vceo=30V, Ic=50mA |
---|---|
Input signal (3) |
Selectable/configurable Input is ON when shorted to COM terminal by contact (relay switch, etc.) or non contact (transistor, open collector, etc.). * DC24V external power supply is required. |
Interface | |
USB | USB interface |
---|---|
EIP | EtherNet/IP interface |
General performance | |
Power supply voltage | DC24V (±15%) |
---|---|
Power consumption | 4W typ |
Operating conditions |
Temperature: Operating temperature range: -10¡æ to +50¡æ, Storage temperature range: -20¡æ to +85¡æ Humidity: 85%RH or less (non-condensing) |
Dimensions | 34(W)×88(H)×91(D)mm (Projections excluded) |
Weight | Approx. 230g |
CE marking certification | EMC Directives EN61326-1 |
Attachments | |
Jumper cable | 2 |
---|---|
Mini driver | 1 |
Various I/O connector | 2 |
Quick manual | 2 |
Download
Product catalogue(PDF)
|
FC400 Weighing Catalogue(1 MB) |
---|