Installed sound applications often demand both high and low impedance connectivity in the same venue, requiring separate, dedicated amplifiers or an external transformer.
Model: XMV4140 Specifications | |
Output Power |
1kHz, THD+N = 1% (20 ms Burst) 4Ω:140W x 4 8Ω:140W x 4 4Ω/ Double Power Mode:280W x 2 8Ω/ Double Power Mode:280W x 2 |
High impedance | |
100V line | 125W x 4 / 80 Ω |
70V line | 125W x 4 / 40 Ω |
Voltage Gain | |
RL=8Ω | 28.7dB |
RL=8Ω / Double Power Mode | 31.7dB |
100V | 38.2dB |
70V | 35.2dB |
Input Sensitivity | |
RL=8Ω | +4dBu |
S/N Ratio | |
A-weighted | ≥ 100dB |
Power Consumption | |
1/8 power (4 Ω pink noise) | 150W |
Idle (4 Ω) | 37W |
Standby | 18.5W |
THD+N | 1kHz, half power: ≤ 0.2% |
Frequency Response | RL=8Ω, 100V/70V, Po=1W, 20Hz - 20kHz 0dB, ±1.0dB |
Crosstalk | 1kHz, half power, 8 Ω, Att. max, input 150 Ω shunt :≤ -60dB |
Maximum Input Level | +24dBu |
Input Impedance | 20kΩ (balanced), 10k Ω (unbalanced) |
Connectors | |
Analog Input | Euroblock x 2 (6P, balanced) |
Digital Input / Output | RJ45 x 2 (YDIF IN / OUT) |
Speaker Output | Barrier strip x 4 pairs |
Network | RJ45 x 1 |
Remote, Fault Output | Euroblock (3P) x 1 |
AC IN | AC Inlet x 1 |
Protection circuit | |
Load Protection | POWER switch on/off: Output mute, DC-fault: Power supply shuts down, Clip limiting |
Amplifier Protection | Thermal: Output mute (heatsink temp ≥90°C) (Restored automatically), Overcurrent: Output mute (Restored automatically), Low load impedance: Output mute (Restored automatically) |
Power Supply Protection | Thermal: Amplifier shuts down automatically (heatsink temp ≥100°C) , Integrated power: Gain reduction (Restored automatically) |
Cooling Fan | 3-Speed fan x 2, front-to-back airflow |
Power Requirements | 100V, 120V, 230V-240V; 50Hz/60Hz |
Dimensions | |
W | 480mm (18.9") |
H | 88mm (3.5") |
D | 422mm (16.6") |
Weight |
8.1kg (17.9lbs) |