For connection with probes FA/FAR (ZS, ZSR, TS, TSR) and measuring tubes FA Di/FAR Di.
Conversion of actual to standard flow / flow rate.
For ATEX category 2G (zone 1) applications, an additional isolation / suppy unit LDX2 is necessary.
With flow-proportional analog output 4-20 mA, relay (potential-free, two-way contact) for use as limit value, quantity pulse or indication of +/- flow direction.
Self-diagnosis according to NAMUR NE43.
Power supply 12 VDC, 24 VDC or 230 VAC.
Configurable via PC interface RS232 and UCOM software.
IP PROTECTION TYPE
IP20
SENSOR INPUT
v/FA; v/FAR
SENSOR OUTPUT
analog output flow 4 ... 20 mA or 0 ... 10 V flow-proportional, relay for limit value, quantity pulse or indication of +/- flow direction, RS232 interface